Description
The JCK4048S05 is the 48 V input, 5 V output member of the XP Power JCK40 series: 40 W in a 50.8 x 25.4 x 10.2 mm metal case with 1600 VDC input-to-output isolation. The 36 V to 75 V input range covers telecom and 48 V industrial bus voltages, and the 5 V rail delivers up to 8 A with efficiency up to 92 percent. Remote on/off, overvoltage, overload and continuous short-circuit protection are built in, and the output is trimmable by plus or minus 10 percent. Operation is specified from -40 to +105 degrees Celsius with derating above +40 degrees Celsius. Typical applications are base station equipment, industrial control cabinets, test systems and railway electronics. Official datasheet: XP Power JCK40 series (SF_JCK40).
Datasheet
Review the complete technical specifications in the official manufacturer datasheet: Download JCK4048S05 datasheet PDF (XP Power).